Factory audit general requirements
To manufacture items for Omnia Technologies a facility must comply with rigorous standards. These ensure high-quality, hygienic, reliable, and sustainable production of complex component mainly paper and plastic. Below a general vademecum with the basic requirements to follow and to implement for a successful start of production.
Security and gate procedures
The factory gate must remain closed at all times, except for authorized entry or exit.
-
Security personnel must be present at the gate before the expected arrival of the audit team.
-
Upon arrival, every visitor (including Ferrero representatives, consultants, or inspectors) must be registered in the Visitor Entry Log, recording:
-
Full name
-
Principal company or organization
-
Reason for visit
-
Valid identification number or document reference
-
Signature of the visitor
-
Time of entry
-
-
Each visitor must be assigned a unique visitor badge.
-
The badge number must be logged in the visitor register together with the above details.
-
The badge must be worn visibly at all times during the visit.
-
-
Security must verify outgoing visitors at the gate, collecting badges and recording exit time and signature.
Factory Cleanliness and External Areas
-
All external areas (entrances, loading zones, driveways, parking, etc.) must remain free from garbage, packaging waste, or scrap materials.
-
Designated garbage collection areas must be:
-
Clearly delimited on the floor with visible painted markings (for example, yellow or red boundary lines).
-
Identified with a fixed, weather-resistant sign or plate, explicitly stating the area’s purpose (e.g., “GARBAGE COLLECTION AREA – AUTHORIZED USE ONLY”).
-
Kept clean, organized, and without overflow, with waste stored in properly closed and labeled containers.
-
No loose waste or unidentified materials should appear outside the marked garbage zones.
-
All floor markings and plate signage must be clean and legible at all times.
-
Standing water or accumulated dirt must be removed unless caused by ongoing rainfall.
General Readiness
-
Ensure security, reception, and line personnel are aware of the audit schedule and visitor protocol.
-
Display safety and hygiene notices in visible areas at the entrance and along main paths.
-
Conduct a final grounds inspection on the morning of the audit to confirm compliance with cleanliness, signage, and safety rules.
Key Responsibilities
-
Security team: Manage access control, visitor registration, and badge distribution.
-
Maintenance/cleaning staff: Keep factory surroundings clean and dry.
-
Quality or audit coordinator: Ensure all procedures are followed and documentation is up to date.
Factory Access doors and openings
-
All factory doors (including production area entrances, warehouse access, and storage gates) must be fully closed at the time of the audit visit.
-
Every door must be equipped with a self-closing mechanism (spring or hydraulic closer) to ensure it shuts automatically and completely after use.
-
No gaps should remain between the door panels and frames once closed — ensure proper alignment and sealing to prevent pest entry or foreign contamination.
-
Damaged or misaligned doors must be repaired immediately and checked for smooth operation.
-
Access doors should only be opened when personnel or materials pass through, and must not be held open unnecessarily during operations or inspections.
Personnel hygiene and dressing requirements
-
All factory personnel must wear clean work blouses or uniforms without buttons.
-
Blouses must be zippered to prevent the risk of physical contamination from loose buttons.
-
Hair nets or caps must be worn by every worker inside production, packing, or quality areas.
-
Visitors must also wear hair nets (and, if required, protective clothing) before entering the production floor.
-
Hair nets and visitor protective gear should be provided and managed by security or QA staff at the entrance to the controlled area.
-
The factory must have separate changing rooms for male and female employees, equipped with lockers for personal clothing and work garments.
-
Dedicated toilets for male and female staff must be available, clean, and well indicated.
-
Toilets should not open directly into production or storage areas.
Chemical and ink storage control
-
All chemicals, inks, solvents, and cleaning agents must be kept in dedicated, locked storage cabinets located in a controlled area away from production lines.
-
Only one designated responsible person (authorized by the factory management or QA department) may hold the cabinet keys and manage access.
-
The identity of the responsible person must be clearly indicated in the chemical control register.
-
Each cabinet must display a clear and legible label or plate on the door specifying:
-
The type of materials stored inside (e.g., printing inks, cleaning chemicals).
-
Safety symbols or hazard pictograms, if applicable.
-
A chemical inventory list must be updated regularly, including batch numbers, quantities, and usage dates.
-
Cabinets should be kept clean, dry, and locked at all times when not in use, with no open containers allowed outside designated areas.
Pest and mosquito control
-
The factory must maintain an active pest monitoring system, covering both mosquitoes and rodents.
-
Mosquito traps must be:
-
Mounted on walls, operational, and connected during the audit visit.
-
Included in a monitoring register showing dates of inspections, observations, maintenance, and responsible personnel.
-
Equipped with identification codes for traceability, marked clearly on the device and in the register.
-
The lifespan of each lamp must be tracked with clear installation and replacement dates.
-
-
Mice traps must be:
-
Installed both inside and outside the factory perimeter, flush against the walls.
-
Mechanical only — no chemical or poison-based traps are permitted.
-
Identified with individual trap codes, consistent with the pest control map and register.
-
Checked and recorded regularly, noting date, time, and the name of the person performing the inspection.
-
-
Both mosquito and mice trap records must be maintained in a dedicated register or digital log, available for examiner review during the audit.
-
The entire pest control system should comply with SMETA and Ferrero standards, and the plan should be signed or validated by the authorized pest control contractor.
Warehouse zoning and labeling
-
The warehouse layout and identification should be clearly defined and controlled for the audit.
-
The warehouse must be physically and visually divided into clearly separated areas.
-
Each area must have large, readable labels/signs indicating at least:
-
“Raw Material Warehouse”
-
“Work in Progress (WIP) Warehouse”
-
“Accessories / Buy Parts Warehouse”
-
“Finished Goods Warehouse”
-
-
Floor markings, rack labels, and hanging signs should all be consistent with the same naming to avoid confusion.
-
Materials must be stored only in the corresponding, identified area, with no mixing between raw materials, WIP, accessories, and finished goods.
Loading bay requirements
-
The loading bay must be covered, providing protection from rain, direct sun, and outside environmental conditions.
-
The loading/unloading area should not be directly exposed to outside temperature; wherever possible, use:
-
A roof or canopy over the full loading area
-
Dock shelters or dock seals to reduce open gaps between truck and dock
-
-
The floor must be clean, dry, and free of debris, and the area should allow smooth, safe transfer of goods from warehouse to vehicle without weather impact.